When "Defining" an interpretation reference channel from a source with a shift and/or a factor those values were not handled properly, and the reference channel ended up with an additional offset/gain.
v2.42.09 - 30 June 2006
Added
Markers can be displayed even on empty user views
Corrected
A problem with a combination of some graphics cards and some video projectors. The problem was revealed by a depth track without labels and a Zone track with huge markers.
In the export option "At Flow Profile" change, the reported depths were supposed to be just within the inflow zones, and they were slightly outside. This caused some small differences in the reported values when compared to those seen in Zone Rates, as the interpolation was taking place in a non stable area.
v2.42.08 - 29 May 2006
Added
Possibility to protect user external DLLs. Please contact KAPPA if you need to use this facility.
v2.42.07 - 15 May 2006
Added
Option to calculate annular phase velocities when inputs are not with respect to full pipe cross section. Access to the option enabled in "Settings - Interpretation".
Corrected
Crash in FSI processing with spinner slopes set to 0
FSI processing was incorrectly interpolating input channels in gaps
FSI processing and stations: cross sections were not always accessible
Condensate PVT: inversion of the values for the heat capacities Cpo and Cpg
v2.42.06 - 8 February 2006
Added
MPa are now available among the Pressure units
Corrected
Crash when selecting the Log page in the Report Print Preview
the CAT processing could not be called in previous versions since January 1st, 2006
v2.42.05 - 6 January 2006
Upgrade number skipped
v2.42.04 - 6 December 2005
Added
Right click on a Well Sketch view to access a dialog that lets you redefine the lateral position of the completion elements
The color of the vertical grid lines may now be defined in Print Setup
FSI image views, cross-sections, and browser processing are now available for stations
Phase velocities added to the FSI processing (in addition to the rates)
Right click in an FSI cross section, and define depths at which the section will be exported in metafile format.
FSI bubble count mnemonics
SIP symbols and colors are used in SIP report table
A signed version of the USB bitlock driver is now included which makes the installation fully transparent on all supported systems, including XP.
Modified
Convention for FSI image view inverted in the 6 inner tracks; the order is now G-O-W
Edition allowed on CaliperC1 and CaliperC2 curves. CaliperC1C2 may be recalculated with a specific browser option
Corrected
The browser FSI processing used the linear interpolation, no matter what interpolation method was chosen in the cross-section dialog.
FSI spinner calibration with stations was not possible (holdups remained N/A)
QZI generated at S.C. showed an incorrect lowest inflow, when using a no flow zone without T/P
MPT raw channels in stations could not be displayed vs time
TIFF output with a defined scale was not always honoring the scale setting
v2.42.03 - 29 April 2005
Added
New option to consider a spinner response function of a mass weighted average
velocity (rather than volume weighted). Activated in Settings - Interpretation
to appear in Zone Rates.
Corrected
A tool bearing mnemo defined at load time was not accessible in the MPT dialog
without quitting and restarting Emeraude.
QZI's at surface conditions used an incorrect FVF
Offset conventions were inverted between the image view and the cross-section
New CAT calibration file
Fill area between 2 curves sometimes had no effect
When loading MPT stationary data, the TIME vector was not loaded properly and it
was not possible to display the measurements versus time
v2.42.02 - 21 February 2005
Version 2.42.02 is the first official 2.42 release. The "Update Notes", Chapter
A03 of the documentation, provide an exhaustive list of additions/modifications
in this version. You can also refer to the on-line help for further explanations.